hm@neelpower.com |
+91-9867382364, +91-8879636610 |
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Current Setting Range | 300 mA to 12 Amps. In step - 300mA / 500mA / 750mA / 1.00A / 1.25 / 1.50 / 1.75 / 2.50 / 3.00 / 4.00 / 5.00 / 6.00 / 7.00 / 8.00 / 9.00 / 10.00 / 11.00 / 12.00 |
Tripping Time | 0.0 Second top 5 Seconds in step of 0.05 Sec |
Instantaneous Tripping Time | less than 35 msec. |
Click to view more |
Preferred Buyer From
Location | Worldwide |
Product Details
At Neelkanth you will get the best ground fault monitoring system Mumbai at an affordable price. We are a reliable and trusted manufacturer and supplier of electrical devices that are required in different sectors.
When planning for electrical system protection, the ground faults present far more common and in aggregate potentially more dangerous occurrences for personnel and the equipment that are used. Bonding, grounding and ground fault protection are extremely vital for reducing the hazards of electrical shocks to the personnel during a ground fault like when a current carrying conducting insulator fails or inadvertently faults to the ground.
Choosing our products for ground fault protection will allow the electrical system to stay maintained and in a reliable manner matching the needs or loads that it serves to isolate undesirable fault conditions In a quick and ideally selective way.
Why Choose Us?
Our products are tested and certified by experts. These are made with advanced machines and technologies and helps in ground fault protection for specific equipment like transformers, generators, motors and much more.
A ground fault usually occurs when the conductor at a voltage other than the earth reference comes in contact with another conductive material that is connected to the ground. Depending on those of the installed grounding system, this can lead to the sustained or transient overvoltage and under-voltage to an undesirable single like to the ground fault currents. These faults can often harm the systems and cause event losses. This is the reason why choosing our products is the best choice for different customers and clients.
Following are some more reasons why you should choose our products and use them for detecting ground faults.
• Provides you with a common reference point
• Improves safety
• Protects your equipment in the best way possible
• Ground fault locations can be detected easily
• Allows you better control of transient overvoltages
• Electrostatic accidents can be better avoided
We have a micro-controlled based ground fault detector in our company as well. Choose us and get our products today.
Technical Specification
Supply Voltage | 230V 50 Hz | Measuring accuracy with closed transformer | +/- 5% |
Power consumption | 70 VA | with split transformer | +/- 10% |
Measuring range | Alarm settings | 30 mA to 9999mA | |
Local measuring point | 10mA to 11A | Time delay setting | to 99 sec. |
Remote measuring point | 30mA to 11A | Alarm relay | -- |
Measuring length | -- | one relay for 16 channels 2 pcs change over contacts max 30 VAC 1.25A |
-- |
Local channel | max 300 ft | Remote channel | max 3000 ft |
Hi! Simply click below and type your query.
Our experts will reply you very soon.